SUNNY TRIPOWER CORE1
SUNNY TRIPOWER CORE1

SUNNY TRIPOWER CORE1 Contact SMA

The Sunny Tripower CORE1 is the world’s first free-standing string inverter for decentralized rooftop and ground-based PV systems as well as covered parking spaces. The CORE1 is the third generation in the successful Sunny Tripower product family and is revolutionizing the world of commercial inverters with its innovative design. SMA engineers developed an inverter that combines a unique design with an innovative installation method to significantly reduce installation time and provide all target groups with a maximum return on investment.

From delivery and installation to operation, the Sunny Tripower CORE1 generates widespread savings in logistics, labor, materials and services. Commercial PV installations are now quicker and easier to complete than ever before.

Cost-Effective

  • Floor-mounted device easy to install
  • No DC fuses required
  • Integrated DC disconnector


Highly Integrated

  • Integrated WLAN access with any mobile device
  • 12 direct string inputs reduce labor and material costs
  • AC/DC overvoltage protection (optional)


Fastest Installation

  • Fast grid connection due to easy inverter configuration and commissioning
  • Completely accessible connection areas


Maximum Yields

  • Up to 150% DC:AC ratio
  • Six independent MPP trackers guarantee optimal energy production for every use, even in shading
MODBUS PROTOCOL INTERFACE

MODBUS PROTOCOL INTERFACE


With the Modbus protocol interface, SMA makes flexible integration of inverters possible. Through the use of this well-known industry standard, you can integrate SMA inverters into your systems without having to follow the SMA-specific inverter protocol.

More

WLAN Antenna Extension

WLAN Antenna Extension


Ambient conditions are not always ideal for a WLAN connection between an inverter and a router. For example, drywall can impair wireless signals significantly, or the inverter might not send its signals correctly because of an installation location that cannot be changed. In this case, simply use the external WLAN antenna extension to increase range even in poor ambient conditions and to ensure a reliable connection with your router.

SMA Sensor Module for monitoring the system

SMA Sensor Module for monitoring the system


The sensor module allows you to record environmental data such as solar irradiation and cell temperature to analyze system performance. This means that any PV system malfunctions can be detected quickly and yield loss minimized. The SMA Sensor Module allows you to connect sensors that measure ambient temperature or wind speed and also provides a simple display for an S0 energy meter.

RS485 Interface

RS485 Interface


The ideal solution for the expansion of existing PV systems that already use RS485 communication. The RS485 interface can be retrofitted and guarantees the proven, cable-based SMA fieldbus communication via RS485 for simple connection to a data logger with a cable length of up to 1,200 meters.

I/O module with Power Control function

I/O Module with Power Control Function


As a multifunction interface, the SMA I/O Module ensures the implementation of grid management services and therefore compliance with the Renewable Energy Sources Act (EEG) 2012.

APPLICATION FOR THE CREATION OF A PUK

  • Type: Forms
  • Language: International
  • Number: PUK-ANTRAG-en-20
  • Version: 2.0

APPLICATION FOR SMA GRID GUARD-CODE

  • Type: Forms
  • Language: English (Worldwide)
  • Number: GRIDGUARD-en-32
  • Version: 3.2

Quick Reference Guide // クイックガイド - ANTENNA EXTENSION KIT (EXTANT-40)

  • Type: Quick reference guide
  • Language: International
  • Number: EXTANT-40-IS-JP-xx-10
  • Version: 1.0

Installation Manual - ANTENNA EXTENSION KIT (EXTANT-40)

  • Type: Installation Guide
  • Language: English (Worldwide)
  • Number: EXTANT-40-IA-en-10
  • Version: 1.0

Installation Manual - SMA SENSOR MODULE - MD.SEN-40 (PC-SENS.BG1)

  • Type: Installation Guide
  • Language: International
  • Number: MDSEN-40-IA-en-10
  • Version: 1.0

Installation Manual - SMA I/O-MODULE - MD.IO-40 (PC-PWC.BG1)

  • Type: Installation Guide
  • Language: English (Worldwide)
  • Number: MD-IO-40-IA-en-10
  • Version: 1.0

Installation manual - SMA RS485 MODULE - MD.485-40 (PC-485.BG1)

  • Type: Installation Guide
  • Language: International
  • Number: MD485-40-IA-en-10
  • Version: 1.0

Certificate IEC 62109-x - SUNNY TRIPOWER CORE1 (STP 50-40)

  • Type: Certificate
  • Language: International
  • Number: ZE_IEC62109_U-17-0542_STP50-40_en_10
  • Version: 1.0

Certificate of compliance with EN61000-3-x and EN61000-6-x for SUNNY TRIPOWER CORE1 (STP 50-40)

  • Type: Certificate
  • Language: International
  • Number: ZE_EN 61000-3-x_STP 50-40_en_10
  • Version: 1.0

Certificate G59/3 - SUNNY TRIPOWER CORE1 (STP 50-40)

  • Type: Certificate
  • Language: English (Worldwide)
  • Number: ZE_G59-3_STP50-40_en_10
  • Version: 1.0

Certificate EN 50438/2013 - SUNNY TRIPOWER CORE1 (STP 50-40)

  • Type: Certificate
  • Language: English (Worldwide)
  • Number: HK_EN50438_2013_STP50-40_en_11
  • Version: 1.1

Type Certificate - BDEW for SUNNY STRIPOWER CORE1 (STP 50-40)

  • Type: Certificate
  • Language: International
  • Number: ZE_BDEW_STP50-40_en_10
  • Version: 1.0

Certificate of compliance EN 50438:2013 - SUNNY TRIPOWER CORE1 (STP 50-40)

  • Type: Certificate
  • Language: English (Worldwide)
  • Number: ZE_EN50438_U17-0607_STP50-40_en_10
  • Version: 1.0

Certificate of Compliance IEC 61727 - SUNNY TRIPOWER CORE1 (STP 50-40)

  • Type: Certificate
  • Language: English (Worldwide)
  • Number: ZE_IEC61727_U17-0624_STP50-40_en_10
  • Version: 1.0

Certificate of Suitability AS4777 - SUNNY TRIPOWER CORE 1 (STP 50-40)

  • Type: Certificate
  • Language: English (Worldwide)
  • Number: ZE_AS4777_CoS_STP50-40_en_10
  • Version: 1.0

Manufacturer’s Declaration - Efficiency Warranty

  • Type: Manufacturers Declaration
  • Language: International
  • Number: MPS-ZE-EffiLifetime-en-12
  • Version: 1.2

EU Declaration of Conformity - SUNNY TRIPOWER (STP 50-40)

  • Type: Manufacturers Declaration
  • Language: English (Worldwide)
  • Number: ZE_CE_STP50-40_en_10
  • Version: 1.0

Manufacturer’s Declaration - Confirmation of Compliance with the Requirements of C 10/11:2012

  • Type: Manufacturers Declaration
  • Language: International
  • Number: MPS-ZE-C10_11_2012-en-22
  • Version: 2.2

Manufacturer Declaration - Compliance SMA inverters with the requirements of the Chilean technical regulation

  • Type: Manufacturers Declaration
  • Language: English (Worldwide)
  • Number: HK_STP-NTCO_NTSyCS_en_14
  • Version: 1.4

Declaration of Conformity - Resolution n°7 - Addendum to Amendment n°1 of the Philippine Grid Code

  • Type: Manufacturers Declaration
  • Language: International
  • Number: ZE_Res_No7_STP_en_11
  • Version: 1.1

SUNNY TRIPOWER CORE1 - Stands on its own

  • Type: Data sheet
  • Language: English (Worldwide)
  • Number: STP50-40-DEN1728-V20
  • Version: 2.0

Technische Information - SunSpec®-Modbus®-Schnittstelle // Technical Information - SunSpec® Modbus® Interface

  • Type: Technical information
  • Language: International
  • Number: SunSpec_Modbus-de-en_V19
  • Version: 1.9

Technical Information - SMA SENSOR MODULE (MD.SEN-40) - List of Compatible Products

  • Type: Technical information
  • Language: International
  • Number: MDSEN-40-TI-en-11
  • Version: 1.1

Integrated Plant Control and Q on Demand 24/7 - SUNNY TRIPOWER

  • Type: Technical information
  • Language: English (Worldwide)
  • Number: IPC-QoD24-7-STP-TI-en-16
  • Version: 1.6

Technische Information - Modbus®-Schnittstelle // Technical Information - Modbus® Interface

  • Type: Technical information
  • Language: International
  • Number: SMA_Modbus-de-en_V21
  • Version: 2.1

Technical Information - Short-Circuit Currents - Information on short-circuit currents of SMA PV inverters

  • Type: Technical information
  • Language: English (Worldwide)
  • Number: Iscpv-TI-en-14
  • Version: 1.4

Technical Information - Temperature Derating SUNNY BOY / SUNNY TRIPOWER

  • Type: Technical information
  • Language: English (Worldwide)
  • Number: Temp-Derating-TI-en-14
  • Version: 1.4

SUNNY TRIPOWER CORE1 - Stands on its own. (only for Australien Market)

  • Type: Brochure
  • Language: English (Worldwide)
  • Number: STPCORE1-KAU1702
  • Version: 1.1

SUNNY TRIPOWER CORE1 - Stands on its own.

  • Type: Brochure
  • Language: English (Worldwide)
  • Number: STPCORE1-KEN1702
  • Version: 1.1

Operating manual - SUNNY TRIPOWER CORE1

  • Type: Operating Instructions
  • Language: English (Worldwide)
  • Number: STP50-40-BE-en-12
  • Version: 1.2

SMA Limited Factory Warranty

  • Type: Warranty
  • Language: International
  • Number: COM-RES-GBED-en-41
  • Version: 4.1
Sunny Design

With Sunny Design, you can plan your tailor-made PV system in just a few clicks.

Plan your system now

Contact SMA now

If you have any questions,
please contact SMA.

Contact us