The Sunny Tripower 20000TL/25000TL is the ideal inverter for large-scale commercial and industrial plants. Not only does it deliver extraordinary high yields with an efficiency of 98.4%, but it also offers enormous design flexibility and compatibility with many PV modules thanks to its multistring capabilities and wide input voltage range.

The future is now: the Sunny Tripower 20000TL/25000TL comes with cutting-edge grid management functions such as

Integrated Plant Control, which allows the inverter to regulate reactive power at the point of common coupling. Separate controllers are no longer needed, lowering system costs. Another new feature-reactive power provision on demand (QonDemand24/7).

Efficient

  • Maximum efficiency of 98.4 %


Safe

  • DC surge arrester (SPD type II) can be integrated


Flexible

  • DC input voltage of up to 1,000 V
  • Multistring capability for optimum system design


Innovative

  • Cutting-edge grid management functions with Integrated Plant Control
  • Reactive power available 24/7 (QonDemand24/7)

MODBUS PROTOCOL INTERFACE

With the Modbus protocol interface, SMA makes flexible integration of inverters possible. Through the use of this well-known industry standard, you can integrate SMA inverters into your systems without having to follow the SMA-specific inverter protocol.

More »

Data module with RS485 interface

The ideal solution for the expansion of existing PV systems that already use RS485 communication. The RS485 interface can be retrofitted and guarantees the proven, cable-based SMA fieldbus communication via RS485 for simple connection to a data logger with a cable length of up to 1,200 meters.

SMA Power Control Module

As a multifunction interface, the SMA Power Control Module ensures the implementation of grid management services and therefore compliance with the Renewable Energy Sources Act (EEG) 2012. In addition, the SMA Power Control Module is equipped with a multifunction relay to process various operating states of the inverter.

DC surge arrester (Type II), inputs A and B

Speedwire/Webconnect data module

The Speedwire/Webconnect data module is a Speedwire communication interface with Webconnect function for inverters.

More »

Multifunctional Relay

The multifunction relay can be used for various purposes whereby you select one of six operating modes for controlling the multifunction relay: fault indication, increased self-consumption, load control, battery charging, fan control and signal transmission at the start of feed-in operation.

Language

Data sheet

SUNNY TRIPOWER 20000TL / 25000TL - The versatile specialist for large-scale commercial plants and solar power plants STP25000TL-30-DEN1602-V23web.pdf
  • Type: Data sheet
  • Language: English (Worldwide)
  • Number: STP25000TL-30-DEN1602-V23
  • Version: 2.3
SMA Warranty Concept - Security. Guaranteed. GARANTIE-DEN1609.pdf
  • Type: Data sheet
  • Language: International
  • Number: GARANTIE-DEN1609
  • Version: 1.1

Operating Instructions

Operating Manual - SUNNY TRIPOWER 20000TL / 25000TL STP20-25TL-BE-en-12.pdf
  • Type: Operating Instructions
  • Language: English (Worldwide)
  • Number: STP20-25TL-BE-en-12
  • Version: 1.2

Installation Guide

Installation Manual - MULTIFUNCTION RELAY MFR-NR-IA-en-22W.pdf
  • Type: Installation Guide
  • Language: English (Worldwide)
  • Number: MFR-NR-IA-en-22W
  • Version: 2.2
Installation Manual - SMA POWER CONTROL MODULE (PWCMOD) PCONTROLMOD-IA-en-15W.pdf
  • Type: Installation Guide
  • Language: English (Worldwide)
  • Number: PCONTROLMOD-IA-en-15
  • Version: 1.5

Certificate

Declaration of Conformity - Resolution n°7 - Addendum to Amendment n°1 of the Philippine Grid Code ZE_Res-No-7_STPxx000TL-30_en_10.pdf
  • Type: Certificate
  • Language: English (Worldwide)
  • Number: ZE_Res-No-7_STPxx000TL-30_en_10
  • Version: 1.0
Certificate of Compliance IEC 61727 and IEC 62116 - SUNNY TRIPOWER 20000TL-30 / 25000TL-30 ZE_IEC61727_STPxx000TL-30_en_10.pdf
  • Type: Certificate
  • Language: English (Worldwide)
  • Number: ZE_IEC61727_STPxx000TL-30_en_10
  • Version: 1.0
Certificate in accordance with IEC 60068-2, IEC 61683, IEC 61727, IEC 62116 and IEC 62109 - SUNNY TRIPOWER 20000TL-30 / 25000TL-30 ZE_IECxx_STPx000TL-30_en_10.pdf
  • Type: Certificate
  • Language: English (Worldwide)
  • Number: ZE_IECxx_STPx000TL-30_en_10
  • Version: 1.0
Certificate MEA&PEA for the - STP 20000TL-30 / STP 25000TL-30 ZE_IEC_61727_MEA_PEA_STPxx000TL-30_en_10.pdf
  • Type: Certificate
  • Language: English (Worldwide)
  • Number: ZE_IEC_61727_MEA_PEA_STPxx000TL-30_en_10
  • Version: 1.0
Certificate G59/3 - SUNNY TRIPOWER (20000TL-30 / 25000TL-30) ZE_G59-3_STP25000TL-30_en_10.pdf
  • Type: Certificate
  • Language: English (Worldwide)
  • Number: ZE_G59-3_STP25000TL-30_en_10
  • Version: 1.0
Certificate of compliance with EN50438 for SUNNY TRIPOWER 20000TL-30 / 25000TL-30 ZE_EN50438_STPxx000TL-30_en_10.pdf
  • Type: Certificate
  • Language: English (Worldwide)
  • Number: ZE_EN50438_STPxx000TL-30_en_10
  • Version: 1.0
EN 50438/2007 type test report for SUNNY TRIPOWER( STP 20000TL-30, STP 250000TL-30) with Irish devitation (Ireland) ZE_EN50438_2007_IE_STPxx000TL-30_en_10.pdf
  • Type: Certificate
  • Language: English (Worldwide)
  • Number: ZE_EN50438_2007_IE_STPxx000TL-30_en_10
  • Version: 1.0
Certificate of Suitability - SUNNY TRIPOWER 20000TL-30 / 25000TL-30 ZE_AS4777_STPxx000TL-30_CoS_en_10.pdf
  • Type: Certificate
  • Language: English (Worldwide)
  • Number: ZE_AS4777_STPxx000TL-30_CoS_en_10
  • Version: 1.0
Certificate of Compliance SI4777 for SUNNY TRIPOWER (STP 20000TL-30 / STP 25000TL-30) ZE_SI4777_STPxx000TL-30_en_10.pdf
  • Type: Certificate
  • Language: English (Worldwide)
  • Number: ZE_SI4777_STPxx000TL-30_en_10
  • Version: 1.0
Certificate of compliance with EN61000-3-x and EN61000-6-x for SUNNY TRIPOWER (STP 20000TL-30 / STP 25000TL-30) ZE_EN61000-3-x_STPxx000TL-30_en_10.pdf
  • Type: Certificate
  • Language: International
  • Number: ZE_EN61000-3-x_STPxx000TL-30_en_10
  • Version: 1.0
BDEW Certificate for the SUNNY TRIPOWER 25000TL-30 / 30000TL-30 ZE_BDEW_STPxx000TL-30_en_11.pdf
  • Type: Certificate
  • Language: International
  • Number: ZE_BDEW_STPxx000TL-30_en_11
  • Version: 1.1
Factory Inspection Certificate for Made in European Union SUNNY BOY / SUNNY ISLAND / SUNNY TRIPOWER / SUNNY CENTRAL ZE_Made-in-EU_SB-STP-SC_en_11.pdf
  • Type: Certificate
  • Language: International
  • Number: ZE_Made-in-EU_SB-STP-SC_en_11
  • Version: 1.1

Technical information

Technical Information - Impedance at 175 Hz for PV Systems in France SUNNY BOY / SUNNY MINI CENTRAL / SUNNY TRIPOWER / FLX PRO Impedanz-175Hz-TI-en-27.pdf
  • Type: Technical information
  • Language: English (Worldwide)
  • Number: Impedanz-175Hz-TI-en-27
  • Version: 2.7
Efficiency and Derating - SUNNY BOY / SUNNY TRIPOWER / SUNNY MINI CENTRAL WirkungDerat-TI-en-40.pdf
  • Type: Technical information
  • Language: English (Worldwide)
  • Number: WirkungDerat-TI-en-40
  • Version: 4.0
Overview of the Rotary Switch Settings for SMA PV inverter, status 07/2015 - SUNNY BOY / SUNNY TRIPOWER Drehschalter-LD-TI-en-12.pdf
  • Type: Technical information
  • Language: English (Worldwide)
  • Number: Drehschalter-LD-TI-en-12
  • Version: 1.2
Technical Information - Short-Circuit Currents - Information on short-circuit currents of SMA PV inverters Iscpv-TI-en-12.pdf
  • Type: Technical information
  • Language: English (Worldwide)
  • Number: Iscpv-TI-en-12
  • Version: 1.2
Medium-voltage Transformers - Important requirements for medium-voltage transformers for SUNNY BOY, SUNNY MINI CENTRAL and SUNNY TRIPOWER MV-Trafo-SB_SMC_STP-TI-en-11.pdf
  • Type: Technical information
  • Language: English (Worldwide)
  • Number: MV-Trafo-SB_SMC_STP-TI-en-11
  • Version: 1.1
Technical Information - Temperature Derating for Sunny Boy and Sunny Tripower Temp-Derating-TI-en-13.pdf
  • Type: Technical information
  • Language: English (Worldwide)
  • Number: Temp-Derating-TI-en-13
  • Version: 1.3
Technical Information - Communit Communit-TI-A1-en-22.pdf
  • Type: Technical information
  • Language: English (Worldwide)
  • Number: Communit-TI-A1-en-22
  • Version: 2.2
Información técnica - Communit Communit-TI-A1-es-22.pdf
  • Type: Technical information
  • Language: English (Worldwide)
  • Number: Communit-TI-A1-es-22
  • Version: 2.2
PV Inverters - Use and Settings of PV Inverters in Off-Grid Systems SB-OffGrid-TI-en-42.pdf
  • Type: Technical information
  • Language: English (Worldwide)
  • Number: SB-OffGrid-TI-en-42
  • Version: 4.2
Overvoltage Protection - Lightning Protection and Overvoltage Protection for Sunny Boy and Sunny Tripower U_Schutz-TI-en-13.pdf
  • Type: Technical information
  • Language: English (Worldwide)
  • Number: U_Schutz-TI-en-13
  • Version: 1.3
Criteria for Selecting a Residual-Current Device - Use of Residual-Current Devices for SUNNY BOY, SUNNY MINI CENTRAL and SUNNY TRIPOWER RCD-TI-en-43.pdf
  • Type: Technical information
  • Language: English (Worldwide)
  • Number: RCD-TI-en-43
  • Version: 4.3
Technical Information - Integrated Plant Control and Q on Demand 24/7 - SUNNY TRIPOWER IPC-QoD24-7-STP-TI-en-15.pdf
  • Type: Technical information
  • Language: English (Worldwide)
  • Number: IPC-QoD24-7-STP-TI-en-15
  • Version: 1.5
Technische Information - SunSpec®-Modbus®-Schnittstelle // Technical Information - SunSpec® Modbus® Interface SunSpec_Modbus-de-en_V12.zip
  • Type: Technical information
  • Language: International
  • Number: SunSpec_Modbus-de-en_V12
  • Version: 1.2
Technische Information - Modbus®-Schnittstelle // Technical Information - Modbus® Interface SMA_Modbus-de-en_V12.zip
  • Type: Technical information
  • Language: International
  • Number: SMA_Modbus-de-en_V12
  • Version: 1.2
Technical Information - Plant Communication in Large-Scale PV Power Plants and Rules for Network Planning SC-PO-TI-en-33.pdf
  • Type: Technical information
  • Language: International
  • Number: SC-PO-TI-en-33
  • Version: 3.3
Technical Information - Circuit breakers LSS-TI-en-44.pdf
  • Type: Technical information
  • Language: English (Worldwide)
  • Number: LSS-TI-en-44
  • Version: 4.4

Service instructions

Service Manual for Installers - SUNNY TRIPOWER 20000TL / 25000TL STP20-25TL-SG-en-11.pdf
  • Type: Service instructions
  • Language: English (Worldwide)
  • Number: STP20-25TL-SG-en-11
  • Version: 1.1

Quick reference guide

Quick Installation Guide - SUNNY TRIPOWER 20000TL / 25000TL STP20-25TL-30-IS-xx-11.pdf
  • Type: Quick reference guide
  • Language: International
  • Number: STP 20-25TL-IS-xx-11
  • Version: 1.1

Manufacturers Declaration

Manufacturer’s Declaration - Usage of residual-current devices (RCD) of type A with Sunny Boy or Sunny Tripower inverters HK_RCD-Typ-A_en_12.pdf
  • Type: Manufacturers Declaration
  • Language: English (Worldwide)
  • Number: HK_RCD-Typ-A_en_12
  • Version: 1.2
Manufacturer’s Declaration - Coastal installation of Sunny Boy and Sunny Tripower Inverters HK_MeeresnaheAufstellung_en_12.pdf
  • Type: Manufacturers Declaration
  • Language: English (Worldwide)
  • Number: HK_MeeresnaheAufstellung_en_12
  • Version: 1.2
Manufacturer’s Declaration - Romanian Technical Standard: Technical Conditions for Connection of the Photovoltaic Power Plants to Public Electrical Grids SB-STP-ZE-HK-PEG_RO-en-13.pdf
  • Type: Manufacturers Declaration
  • Language: English (Worldwide)
  • Number: SB-STP-ZE-HK-PEG_RO-en-13
  • Version: 1.3
Manufacturer Declaration - Compliance of Sunny Tripower inverters with the requirements of the Chilean technical regulation HK_STP-Einhaltung-technische-Anforderungen-Chile_en_13.pdf
  • Type: Manufacturers Declaration
  • Language: English (Worldwide)
  • Number: HK_STP-Einhaltung-technische-Anforderungen-Chile_en_13
  • Version: 1.3
EU Declaration of Conformity - SUNNY TRIPOWER (STP 20000TL-30 / STP 25000TL-30) ZE_CE_STPxx000TL-30_en_12.pdf
  • Type: Manufacturers Declaration
  • Language: English (Worldwide)
  • Number: ZE_CE_STPxx000TL-30_en_12
  • Version: 1.2
Manufacturer’s Declaration - Confirmation of Compliance with the Requirements of C 10/11:2012 MPS-ZE-C10_11_2012-en-19.pdf
  • Type: Manufacturers Declaration
  • Language: English (Worldwide)
  • Number: MPS-ZE-C10_11_2012-en-19
  • Version: 1.9
Manufacturer’s Declaration - Compatibility of SMA Inverters with PID Solutions KOMP-SMA-INV-PID-en-10.pdf
  • Type: Manufacturers Declaration
  • Language: International
  • Number: KOMP-SMA-INV-PID-en-10
  • Version: 1.0
Manufacturer's Declaration - Static MPPT Efficiency of 99.8% with OptiTrac ZE-HK-MPPT-SB-STP-SC-en-13.pdf
  • Type: Manufacturers Declaration
  • Language: International
  • Number: ZE-HK-MPPT-SB-STP-SC-en-13
  • Version: 1.3

Forms

APPLICATION FOR SMA GRID GUARD-CODE GRIDGUARD-ZEN151321.pdf
  • Type: Forms
  • Language: English (Worldwide)
  • Number: GRIDGUARD-ZEN151321
  • Version: 2.1
ORDER FORM - SMA REMOTE SERVICE BRemote-ZE-en-16.pdf
  • Type: Forms
  • Language: International
  • Number: BRemote-ZE-en-16
  • Version: 1.6