SUNNY CENTRAL 1000CP XT

SUNNY CENTRAL 1000CP XT

The most powerful CP with an output of 1 megawatt

For increased power: With its expanded functions and a peak power of 1100 kVA, the new Sunny Central 1000CP XT is now even more powerful. With its proven technology and high power density, the SC 1000CP XT completes the worldwide most successful Sunny Central CP inverter family for PV. The central inverter for outdoor use is optimized for both full nominal power in continuous operation up to 40°C and cold temperatures as low as -40°C. The inverter includes all grid management functions and is prepared for Q at Night, including pure reactive power management. The customized computing platform allows optimal monitoring and control.

Profitable

  • 1 MW system power as standard
  • High power density for reduced transportation costs
  • Maximum yields with low system costs


Robust

  • Full nominal power in continuous operation at ambient temperatures up to 40 °C
  • Direct installation on-site, optimized for extreme climatic conditions of between -40°C and 62°C
  • OptiCool for active temperature management


Flexible

  • Wide DC input voltage range for flexible use of various module configurations
  • Perfectly adjusted to temperature-dependent behavior of PV arrays


Versatile

  • All grid management functions included, prepared for Q at Night
  • Optimal monitoring and control thanks to customized computing platform
Language

User Manual

User Manual - SUNNY CENTRAL 500CP XT / 630CP XT / 720CP XT / 760CP XT / 800CP XT / 850CP XT / 900CP XT / 1000CP XT SCCPXT-BA-E7-en-55.pdf
  • Type: User Manual
  • Language: English (Worldwide)
  • Number: SCCPXT-BA-E7-en-55
  • Version: 5.5

Data sheet

SUNNY CENTRAL 1000CP XT - The most powerful CP with an output of 1 megawatt SC1000CP-DEN1529-V21web.pdf
  • Type: Data sheet
  • Language: English (Worldwide)
  • Number: SC1000CP-DEN1529-V21
  • Version: 2.1

Operating Instructions

SUNNY CENTRAL COMMUNICATION CONTROLLER - Operating Manual SC-COM-BE-en-20.pdf
  • Type: Operating Instructions
  • Language: English (Worldwide)
  • Number: SC-COM-BE-en-20
  • Version: 2.0

Installation Guide

Installation Manual - SUNNY STRING-MONITOR SSM8-21-BS / SSM16-21-BS / SSM8-21-BS-JP / SSM16-21-BS-JP SSMxx-21-IA-BS-JP-en-20.pdf
  • Type: Installation Guide
  • Language: English (Worldwide)
  • Number: SSMxx-21-IA-BS-JP-en-20
  • Version: 2.0
Installation Manual - SUNNY CENTRAL 500CP XT / 630CP XT / 720CP XT / 760CP XT / 800CP XT / 850CP XT / 900CP XT / 1000CP XT SCCPXT-IA-E7-en-45.pdf
  • Type: Installation Guide
  • Language: English (Worldwide)
  • Number: SCCPXT-IA-E7-en-45
  • Version: 4.5
Installation Manual - Retrofitting of the Option 'Noise Reduction' SUNNY CENTRAL of the CP XT Series and SUNNY CENTRAL STORAGE SCCPXT-SCS_NR-IA-en-11.pdf
  • Type: Installation Guide
  • Language: English (Worldwide)
  • Number: SCCPXT-SCS_NR-IA-en-11
  • Version: 1.1

Brochure

SMA Power Plant Solutions - Solutions for Profitable PV Power Plants - Cutting-Edge Applications for Utility-Scale PV Projects KOMPETENZ_PPS-KEN131230W.pdf
  • Type: Brochure
  • Language: English (Worldwide)
  • Number: KOMPETENZ_PPS-KEN131230
  • Version: 3.0
Quality Makes the Difference - Your partner for utility-scale PV EN – now and in the future QUALI-AEN132613W.pdf
  • Type: Brochure
  • Language: English (Worldwide)
  • Number: QUALI-AEN132613W
  • Version: 1.3
SMA Service - Maintenance for Optimum Plant Performance // Service for Sunny Central Inverters and Medium-Voltage Components SC_FS_WARTUNG-KEN1609.pdf
  • Type: Brochure
  • Language: English (Worldwide)
  • Number: SC_FS_WARTUNG-KEN1609
  • Version: 1.0
SMA SERVICE FOR PV POWER PLANTS - Successful Projects with Sunny Central System Solutions SERVICE-SC-KEN1609.pdf
  • Type: Brochure
  • Language: International
  • Number: SERVICE-SC-KEN1609
  • Version: 3.1

Certificate

Type Certificate - BDEW for SUNNY CENTRAL CP (XT) ZE_BDEW_SCxxxxCPXT_en_61.pdf
  • Type: Certificate
  • Language: International
  • Number: ZE_BDEW_SCxxxxCPXT_en_61
  • Version: 6.1
Factory Inspection Certificate for Made in European Union SUNNY BOY / SUNNY ISLAND / SUNNY TRIPOWER / SUNNY CENTRAL ZE_Made-in-EU_SB-STP-SC_en_12.pdf
  • Type: Certificate
  • Language: International
  • Number: ZE_Made-in-EU_SB-STP-SC_en_12
  • Version: 1.2

Technical information

Technical Information - Communit Communit-TI-A1-en-22.pdf
  • Type: Technical information
  • Language: English (Worldwide)
  • Number: Communit-TI-A1-en-22
  • Version: 2.2
Información técnica - Communit Communit-TI-A1-es-22.pdf
  • Type: Technical information
  • Language: English (Worldwide)
  • Number: Communit-TI-A1-es-22
  • Version: 2.2
Q at Night - Reactive power outside feed-in operation with the SUNNY CENTRAL series CP XT, CP-JP and CP-US Q-at-Night-TI-en-11.pdf
  • Type: Technical information
  • Language: English (Worldwide)
  • Number: Q-at-Night-TI-en-11
  • Version: 1.1
SUNNY CENTRAL COMMUNICATION CONTROLLER SC-COM-TI-en-13.pdf
  • Type: Technical information
  • Language: English (Worldwide)
  • Number: SC-COM-TI-en-13
  • Version: 1.3
Installation at high altitudes - Design of Central Inverters for Mounting Locations above 2,000 m MSL SUNNY CENTRAL xxxCP XT CP-Hoehenaufst-TI-en-12.pdf
  • Type: Technical information
  • Language: English (Worldwide)
  • Number: CP-Hoehenaufst-TI-en-12
  • Version: 1.2
Transportation and Installation Requirements - SUNNY CENTRAL 500CP XT/630CP XT/720CP XT/760CP XT/800CP XT/850CP XT/900CP XT/1000CP XT SCCPXT-TA-E7-en-72.pdf
  • Type: Technical information
  • Language: English (Worldwide)
  • Number: SCCPXT-TA-E7-en-72
  • Version: 7.2
Technical Information - Plant Communication in Large-Scale PV Power Plants SC-PO-TI-en-34.pdf
  • Type: Technical information
  • Language: English (Worldwide)
  • Number: SC-PO-TI-en-34
  • Version: 3.4
Technical Information - Requirement for MV Transformers and Transformer for Internal Power Supply for SUNNY CENTRAL SC_Trafo-TI-en-63.pdf
  • Type: Technical information
  • Language: English (Worldwide)
  • Number: SC_Trafo-TI-en-63
  • Version: 6.3

Maintenance Manual

Maintenance Manual - SUNNY CENTRAL 500CP XT / 630CP XT / 720CP XT / 760CP XT / 800CP XT / 850CP XT / 900CP XT / 1000CP XT SCCPXT-WA-E7-en-35.pdf
  • Type: Maintenance Manual
  • Language: English (Worldwide)
  • Number: SCCPXT-WA-E7-en-35
  • Version: 3.5

Maintenance protocol

Maintenance Report - SUNNY CENTRAL 500CP XT/630CP XT/720CP XT/760CP XT/800CP XT/850CP XT/900CP XT/1000CP XT SCCPXT-WP-E7-en-34.pdf
  • Type: Maintenance protocol
  • Language: English (Worldwide)
  • Number: SCCPXT-WP-E7-en-34
  • Version: 3.4

Planning guidelines

Planning of a PV Generator - Planning Guidelines DC-PL-en-11.pdf
  • Type: Planning guidelines
  • Language: English (Worldwide)
  • Number: DC-PL-en-11
  • Version: 1.1