SUNNY CENTRAL 800CP XT

SUNNY CENTRAL 800CP XT / 850CP XT / 900CP XT

The extended CP XT: peak output up to 1 megawatt

For increased power: With its expanded functions, the new Sunny Central CP XT series is now even more powerful. Moreover, the specific price is going down, meaning that maximum yields are achieved with lower system costs. Apart from providing full nominal power in continuous operation up to 50 °C, the Sunny Central CP XT is also optimized for operation in cold temperatures as low as -40 °C. The inverter encompasses all grid management functions, including Q at Night. The customized computer platform can be used for optimal monitoring and control.

Profitable

  • Up to 1 megawatt system power as standard
  • Significantly reduced specific price thanks to increased power
  • Maximum yields with low system costs

Durable

  • Full nominal power in continuous operation at ambient temperatures up to 50 °C
  • Optimized for extreme climatic conditions between -40 °C and +62 °C
  • Intelligent power management with OptiCool ™

Flexible

  • Wide DC input voltage range for flexible use of various module configurations
  • Perfectly adjusted for the temperature- dependent behavior of PV arrays

Versatile

  • Encompasses all grid management functions, including nighttime reactive power operation
  • Customized computer platform for optimal monitoring and inverter control

Contact

SMA Solar Technolgy AG

Sonnenallee 1
34266 Niestetal, Germany

Tel. +49 561 9522-4000
Fax +49 561 9522-4040

powerplants@SMA.de

SMA worldwide »

Extended Warranty

SMA stands for high standards and excellent quality. Our inverters come with a five-year manufacturer’s warranty.

Order now »

Show All / Hide All SUNNY CENTRAL 800CP XT SUNNY CENTRAL 850CP XT SUNNY CENTRAL 900CP XT
Input (DC)
Max. DC power (@ cos φ=1) 898 kW 954 kW 1010 kW
Max. input voltage 1000 V 1000 V 1000 V
Minimum input voltage / UMPP_min at IMPP < IDCmax 535 V / 535 V 570 V / 570 V 600 V / 600 V
MPP voltage range (@ 25 °C / @ 50 °C at 50 Hz) 1) 641 V – 850 V / 583 V – 850 V², ³ 681 V – 850 V / 620 V – 850 V² 722 V – 850 V / 656 V – 850 V²
MPP voltage range (@ 25 °C / @ 50 °C at 60 Hz) 641 V – 850 V / 583 V – 850 V², ³ 681 V – 850 V / 620 V – 850 V² 722 V – 850 V / 656 V – 850 V²
Rated input voltage 620 V 620 V 620 V
Max. input current 1400 A 1400 A 1400 A
Number of independent MPP inputs 1 1 1
Number of DC inputs 9 / 32 (Optiprotect) 9 / 32 (Optiprotect) 9 / 32 (Optiprotect)
Output (AC)
Rated power (@ 25 °C) / nominal AC power (@ 50 °C) 880 kVA / 800 kVA 935 kVA / 850 kVA 990 kVA / 900 kVA
Nominal AC voltage / range 360 V / 324 V – 396 V³ 386 V / 348 V – 425 V 405 V / 364 V – 446 V
AC power frequency / range 50 Hz, 60 Hz / 47 Hz ... 63 Hz 50 Hz, 60 Hz / 47 Hz ... 63 Hz 50 Hz, 60 Hz / 47 Hz ... 63 Hz
Rated frequency / rated grid voltage 50 Hz / 360 V 50 Hz / 386 V 50 Hz / 405 V
Max. output current 1411 A 1411 A 1411 A
Max. THD < 3 % < 3 % < 3 %
Power factor at rated power / adjustable shift factor 1 / 0.9 overexcited ... 0.9 underexcited 1 / 0.9 overexcited ... 0.9 underexcited 1 / 0.9 overexcited ... 0.9 underexcited
Feed-in phases / connection phases 3 / 3 3 / 3 3 / 3
Efficiency 7)
Max. efficiency / European efficiency 98.6 % / 98.4 % / 98.5 % 98.6 % / 98.4 % / 98.5 % 98.6 % / 98.4 % / 98.5 %
Protective devices
Input side disconnection device Motor-driven DC switch-disconnector / circuit breaker (Optiprotect) Motor-driven DC switch-disconnector / circuit breaker (Optiprotect) Motor-driven DC switch-disconnector / circuit breaker (Optiprotect)
Output side disconnection device AC circuit breaker AC circuit breaker AC circuit breaker
DC overvoltage protection Type I surge arrester Type I surge arrester Type I surge arrester
Lightning protection (according to IEC 62305-1) Lightning protection level III Lightning protection level III Lightning protection level III
Grid monitoring yes yes yes
Ground fault monitoring / Remote ground fault monitoring opt. / opt. opt. / opt. opt. / opt.
Insulation monitoring opt. opt. opt.
Surge arrester for auxiliary supply yes yes yes
Protection class (as per IEC 62103) / overvoltage category (according to IEC 60664-1) I / III I / III I / III
General data
Dimensions (W / H / D) 2562 / 2279 / 956 mm
(101 / 90 / 38 inch)
2562 / 2279 / 956 mm
(101 / 90 / 38 inch)
2562 / 2279 / 956 mm
(101 / 90 / 38 inch)
Weight 1800 kg / 4000 lb 1800 kg / 4000 lb 1800 kg / 4000 lb
Operating temperature range -25 °C ... +62 °C /
-13 °F ... +144 °F
-25 °C ... +62 °C /
-13 °F ... +144 °F
-25 °C ... +62 °C /
-13 °F ... +144 °F
Noise emission⁵ 61 dB(A) 61 dB(A) 61 dB(A)
Max. self-consumption (in operation) / self-consumption (at night) 1700 W⁴ / < 100 W 1700 W⁴ / < 100 W 1700 W⁴ / < 100 W
External auxiliary supply voltage 230 / 400 V (3/N/PE) 230 / 400 V (3/N/PE) 230 / 400 V (3/N/PE)
Cooling concept OptiCool OptiCool OptiCool
Electronics degree of protection / connection area (according to IEC 60529) IP54 / IP43 IP54 / IP43 IP54 / IP43
Degree of protection (according to IEC 60721-3-4) 4C2, 4S2 4C2, 4S2 4C2, 4S2
Application Unprotected outdoors Unprotected outdoors Unprotected outdoors
Maximum permissible value for relative humidity (non-condensing) 15 % ... 95 % 15 % ... 95 % 15 % ... 95 %
Maximum operating altitude above MSL 2000 m 2000 m 2000 m
Fresh air consumption 3000 m³/h 3000 m³/h 3000 m³/h
Features
DC connection Ring terminal lug / cage clamp (Optiprotect) Ring terminal lug / cage clamp (Optiprotect) Ring terminal lug / cage clamp (Optiprotect)
AC connection Ring terminal lug Ring terminal lug Ring terminal lug
Display HMI touchscreen HMI touchscreen HMI touchscreen
Communication / protocols Ethernet (OF optional), Modbus Ethernet (OF optional), Modbus Ethernet (OF optional), Modbus
Sunny String-Monitor communication RS485 / none (Optiprotect) RS485 / none (Optiprotect) RS485 / none (Optiprotect)
SC Com yes yes yes
Color of enclosure / door / base / roof RAL 9016 / 9016 / 7005 / 7004 RAL 9016 / 9016 / 7005 / 7004 RAL 9016 / 9016 / 7005 / 7004
Warranty: 5 / 10 / 15 / 20 / 25 years yes / opt. / opt. / opt. / opt. yes / opt. / opt. / opt. / opt. yes / opt. / opt. / opt. / opt.
Certificates and approvals (more upon request) EN 61000-6-2, EN 61000-6-4, CE conformity, EEG conformity, BDEW-MSRL / FGW / TR86, Arrêté du 23/04/08, R.D. 1663 / 2000, R.D. 661 / 2007 EN 61000-6-2, EN 61000-6-4, CE conformity, EEG conformity, BDEW-MSRL / FGW / TR86, Arrêté du 23/04/08, R.D. 1663 / 2000, R.D. 661 / 2007 EN 61000-6-2, EN 61000-6-4, CE conformity, EEG conformity, BDEW-MSRL / FGW / TR86, Arrêté du 23/04/08, R.D. 1663 / 2000, R.D. 661 / 2007
Footnotes
Type designation SC 800CP-10 SC 850CP-10 SC 900CP-10
1) Start-up at DC voltage < 1000 V
2) At 1.05 UAC, nom and cos φ = 1
3) Further AC voltages, DC voltages and power classes can be configured
4) Self-consumption at rated operation
5) Sound pressure level at a distance of 10 m
6) With complete dynamic grid support, approval for SC850CP and SC900CP from 08/2012
7)Efficiency measured without internal power supply

Sunny String-Monitor SSM / SSM16-11 / SSM24-11

Detailed plant control: the Sunny String-Monitor watches over the PV array by measuring and comparing individual string currents. This allows certain detection of reductions in performance, which can be directly analyzed via Sunny Central Control. Delivered in an enclosure for wall installation (IP 65).

SMA String Combiner

Sunny Main Box Cabinet

 

Disconnect Unit

Contact

SMA Solar Technolgy AG

Sonnenallee 1
34266 Niestetal, Germany

Tel. +49 561 9522-4000
Fax +49 561 9522-4040

powerplants@SMA.de

SMA worldwide »

Extended Warranty

SMA stands for high standards and excellent quality. Our inverters come with a five-year manufacturer’s warranty.

Order now »

Language

Installation Guide

SUNNY CENTRAL 500CP / 630CP / 720CP / 760CP / 800CP - SMB Connection Kit SMB-Kit-BB-IEN111011.pdf
  • Type: Installation Guide
  • Language: English (Worldwide)
  • Number: SMB-Kit-BB-IEN111011
  • Version: 1.1
SUNNY CENTRAL CP and HE-20 - Sealing - Additional sheet Plomb-BB-IEN112920.pdf
  • Type: Installation Guide
  • Language: English (Worldwide)
  • Number: Plomb-BB-IEN112920
  • Version: 2.0
SUNNY STRING-MONITOR SSM8-21 / SSM16-21 / SSM24-21 - Installation Manual SSMxx-21-IA-A7-en-12.pdf
  • Type: Installation Guide
  • Language: English (Worldwide)
  • Number: SSMxx-21-IA-A7-en-12
  • Version: 1.2
Installation Manual - SUNNY CENTRAL 500CP XT/630CP XT/720CP XT/760CP XT/800CP XT/850CP XT/900CP XT SCCPXT-IA-D7-en-42.pdf
  • Type: Installation Guide
  • Language: English (Worldwide)
  • Number: SCCPXT-IA-D7-en-42
  • Version: 4.2

Maintenance Manual

SUNNY CENTRAL 500CP XT / 630CP XT / 720CP XT / 760CP XT / 800CP XT / 850CP XT / 900CP XT - Maintenance Manual SCCP-WH-D7-en-32.pdf
  • Type: Maintenance Manual
  • Language: English (Worldwide)
  • Number: SCCP-WH-D7-en-32
  • Version: 3.2

Operating Instructions

SUNNY CENTRAL COMMUNICATION CONTROLLER - Operating Manual SC-COM-BE-en-20.pdf
  • Type: Operating Instructions
  • Language: English (Worldwide)
  • Number: SC-COM-BE-en-20
  • Version: 2.0

Technical Manual

Planning of a PV Generator - Planning Guidelines DC-PL-en-11.pdf
  • Type: Technical Manual
  • Language: English (Worldwide)
  • Number: DC-PL-en-11
  • Version: 1.1

User Manual

User Manual - SUNNY CENTRAL 500CP XT / 630CP XT / 720CP XT / 760CP XT / 800CP XT / 850CP XT / 900CP XT SCCPXT-BA-D7-en-52.pdf
  • Type: User Manual
  • Language: English (Worldwide)
  • Number: SCCPXT-BA-D7-en-52
  • Version: 5.2

Catalog

INSIGHTS Edition 01 - Extreme Conditions Require Experience INSIGHTS01-AEN132412W.PDF
  • Type: Catalog
  • Language: English (Worldwide)
  • Number: INSIGHTS01-AEN132412W
  • Version: 1.2
SMA Service Concept - SUNNY CENTRAL SERVICECON-KEN132518_web.pdf
  • Type: Catalog
  • Language: English (Worldwide)
  • Number: SERVICECON-KEN132518
  • Version: 1.8
SUNNY FAMILY 2012 - PRODUCT CATALOG SOLARKAT-KEN122111.pdf
  • Type: Catalog
  • Language: English (Worldwide)
  • Number: SOLARKAT-KEN122111
  • Version: 1.1
Experience meets Peak Performance - The Megawatt Solution Megawatt-KEN122210W.pdf
  • Type: Catalog
  • Language: English (Worldwide)
  • Number: Megawatt-KEN122210
  • Version: 1.0
Quality Makes the Difference - Your partner for utility-scale PV EN – now and in the future QUALI-AEN131511W.pdf
  • Type: Catalog
  • Language: English (Worldwide)
  • Number: QUALI-AEN131511
  • Version: 1.1
Quality Makes the Difference - Your partner for utility-scale PV EN – now and in the future QUALI-AEN132613W.pdf
  • Type: Catalog
  • Language: English (Worldwide)
  • Number: QUALI-AEN132613W
  • Version: 1.3
OPTIPROTECT - Intelligent error management for higher plant yields OPTIPRO-AEN121210W.pdf
  • Type: Catalog
  • Language: English (Worldwide)
  • Number: OPTIPRO-AEN121210
  • Version: 1.0
INSIGHTS Edition 02 - PV POWER PLANTS: THE FUTURE OF POWER GRIDS INSIGHTS02-AEN120810W.pdf
  • Type: Catalog
  • Language: English (Worldwide)
  • Number: INSIGHTS02-AEN120810
  • Version: 1.0
INSIGHTS Edition 04 - QUALITY IS THE FUTURE INSIGHTS04-AEN130710W.PDF
  • Type: Catalog
  • Language: English (Worldwide)
  • Number: INSIGHTS04-AEN130710
  • Version: 1.0
SMA Power Plant Solutions - Solutions for Profitable PV Power Plants - Cutting-Edge Applications for Utility-Scale PV Projects KOMPETENZ_PPS-KEN131230W.pdf
  • Type: Catalog
  • Language: English (Worldwide)
  • Number: KOMPETENZ_PPS-KEN131230
  • Version: 3.0
INSIGHTS Edition 03 - EMERGING PV MARKETS INSIGHTS03-AEN132411W.PDF
  • Type: Catalog
  • Language: English (Worldwide)
  • Number: INSIGHTS03-AEN132411W
  • Version: 1.1
Next Innovations 2013 - NEW PRODUCT RELEASES NEXTINNO-KEN132211W.pdf
  • Type: Catalog
  • Language: English (Worldwide)
  • Number: NEXTINNO-KEN132211
  • Version: 1.1

Data sheet

Premium project management - Worldwide expertise and seamless support Project-Management-DEN122114W.pdf
  • Type: Data sheet
  • Language: English (Worldwide)
  • Number: Project-Management-DEN122114
  • Version: 1.4
SUNNY STRING-MONITOR - Insurance for energy yields SSM-21-DEN131713W.pdf
  • Type: Data sheet
  • Language: English (Worldwide)
  • Number: SSM-21-DEN131713
  • Version: 1.3
SUNNY CENTRAL 800CP XT / 850CP XT / 900CP XT - The extended CP: peak output up to 1 megawatt SC800CP-900CP-DEN131915W.pdf
  • Type: Data sheet
  • Language: English (Worldwide)
  • Number: SC800CP-900CP-DEN131915
  • Version: 1.5
SMA Service Concept SUNNY CENTRAL - Security with a modular approach SCKONZEPT-DEN122110W.pdf
  • Type: Data sheet
  • Language: English (Worldwide)
  • Number: SCKONZEPT-DEN122110
  • Version: 1.0

Technical information

Communit - Communication Distributor for PV Plants for SUNNY CENTRAL, SUNNY MINI CENTRAL or SUNNY TRIPOWER Communit-TI-en-20.pdf
  • Type: Technical information
  • Language: English (Worldwide)
  • Number: Communit-TI-en-20
  • Version: 2.0
Plant Communication in Large-Scale PV Power Plants - Rules for Network Planning SC-PO-TI-en-31.pdf
  • Type: Technical information
  • Language: English (Worldwide)
  • Number: SC-PO-TI-en-31
  • Version: 3.1
SUNNY CENTRAL COMMUNICATION CONTROLLER SC-COM-TI-en-13.pdf
  • Type: Technical information
  • Language: English (Worldwide)
  • Number: SC-COM-TI-en-13
  • Version: 1.3
SUNNY STRING-MONITOR SSM8-21 / SSM16-21 / SSM24-21 - Technical Information SSMxx-21-TI-en-12.pdf
  • Type: Technical information
  • Language: English (Worldwide)
  • Number: SSMxx-21-TI-en-12
  • Version: 1.2
Design of Central Inverters for Mounting Locations above 2,000 m MSL SUNNY CENTRAL xxxCP XT - Technical Information CP-Hoehenaufst-TI-en-10.pdf
  • Type: Technical information
  • Language: English (Worldwide)
  • Number: CP-Hoehenaufst-TI-en-10
  • Version: 1.0
Q at Night - Reactive power outside of feed-in operation with SUNNY CENTRAL 500CP XT / 630CP XT / 720CP XT / 760CP XT / 800CP XT / 850CP XT / 900CP XT Q-at-Night-TI-en-10.pdf
  • Type: Technical information
  • Language: English (Worldwide)
  • Number: Q-at-Night-TI-en-10
  • Version: 1.0
SUNNY CENTRAL Inverters of the HE-20 and CP Series - Unpacking and Transport Manual SCxxxHE20-AP-IEN114110.pdf
  • Type: Technical information
  • Language: English (Worldwide)
  • Number: SCxxxCP_HE20-AP-IEN114110
  • Version: 1.0
Mounting and Technical Data - Sunny Main Box / Sunny Main Box Cabinet SMB_SMB-C-TI-en-30.pdf
  • Type: Technical information
  • Language: English (Worldwide)
  • Number: SMB_SMB-C-TI-en-30
  • Version: 3.0
Cable Set - Requirements for and Laying of Cables between SUNNY CENTRAL CP and TRANSFORMER COMPACT STATION Kabelvb-TI-en-11.pdf
  • Type: Technical information
  • Language: English (Worldwide)
  • Number: Kabelvb-TI-en-11
  • Version: 1.1
COM-B - Communication distributor for large-scale plants with SUNNY CENTRAL, SUNNY MINI CENTRAL or SUNNY TRIPOWER COM-B-UEN103923.pdf
  • Type: Technical information
  • Language: English (Worldwide)
  • Number: COM-B-UEN103923
  • Version: 2.3

Certificate

Type Certificate according to BDEW Medium-Voltage Guideline - GL Renewables - SCxxxCP/SCxxxCP XT SCxxxCPXT-ZE-GL-en-10.pdf
  • Type: Certificate
  • Language: English (Worldwide)
  • Number: SCxxxCPXT-ZE-GL-en-10
  • Version: 1.0
EC Declaration of Conformity - SUNNY CENTRAL 500CP-JP, 500CP, 630CP, 720CP, 760CP, 800CP SCCP-ZE-en-12.pdf
  • Type: Certificate
  • Language: English (Worldwide)
  • Number: SCCP-ZE-en-12
  • Version: 1.2
EC Declaration of Conformity - SUNNY CENTRAL 500CP XT, 630CP XT, 720CP XT, 760CP XT, 800CP XT, 850CP XT, SC 900CP XT SCCP-XT-JP-ZE-CP-en-13.pdf
  • Type: Certificate
  • Language: English (Worldwide)
  • Number: SCCP-XT-JP-ZE-CP-en-13
  • Version: 1.3
Made in EU certificate Qinto Conto Energia §4.4.1 & 4.6.1 - SUNNY BOY/SUNNY MINI CENTRAL/SUNNY TRIPOWER/SUNNY CENTRAL SB-STP-SC-ZE-FIC-IT-en-12.pdf
  • Type: Certificate
  • Language: English (Worldwide)
  • Number: SB-STP-SC-ZE-FIC-IT-en-12
  • Version: 1.2
Factory inspection Certificate - For Italian Market Fic-ZE-en-11.pdf
  • Type: Certificate
  • Language: English (Worldwide)
  • Number: Fic-ZE-en-11
  • Version: 1.1

Warranty

SMA Manufacturer's Warranty - SUNNY CENTRAL SC-ZE-GEBED-en-28.pdf
  • Type: Warranty
  • Language: English (Worldwide)
  • Number: SC-ZE-GEBED-en-28
  • Version: 2.8

Contact

SMA Solar Technolgy AG

Sonnenallee 1
34266 Niestetal, Germany

Tel. +49 561 9522-4000
Fax +49 561 9522-4040

powerplants@SMA.de

SMA worldwide »

Extended Warranty

SMA stands for high standards and excellent quality. Our inverters come with a five-year manufacturer’s warranty.

Order now »

SMA. Your partner for large-scale PV plants

As the leader in technology and the world market, we offer our customers technology and expertise for PV power plants in the megawatt range.

More information »

References

Learn more about the flexible uses of our products by seeing how they are used at selected reference plants.

To the references »